Abstract
IntroductionMandibular anterior subapical osteotomy (MASO) is a complementary procedure during orthognathic surgery to correct proclination or extrusion of the anterior incisors when orthodontic movements fail. The increasing use of patient-specific implants (PSI, titanium plates) in orthognathic surgery has extended to this procedure. Digital orthognathic surgery planning involves manufacturing cutting/drilling guides and specific implants to provide better accuracy and allow complex movement with reduced surgical times compared to conventional planning. This study aimed to assess the accuracy of computer-aided surgery with patient-specific implants in mobilising the MASO segment according to planning. MethodsEleven consecutive patients with mean age 26.82 years (15–41, SD = 10.65) were treated with MASO in addition to other conventional orthognathic procedures incorporating digital planning and patient-specific implants. A three-dimensional “stl” format file of the mandibular dental arch was obtained using an intraoral scanner at the end of the surgical procedure. The accuracy of the MASO segment displacement imposed by PSI was assessed by comparing preoperative 3D-planned mandibular dental arch with the immediate postoperative 3D-measured arch, using surface superimposition and 7 standard dental landmarks. Deviations between the preoperative and postoperative landmarks were calculated and compared to determine whether MASO segment repositioning is sufficiently accurate to be safely used to reposition the incisor/canine axis. ResultsQuantitative analysis revealed an absolute linear difference of 0.66 mm (SD = 0.51) between preoperative 3D digital dental arch impression and postoperative planned 3D dental arch. Overall, the median absolute discrepancies in the x-axis (right-left direction), y-axis (antero-posterior direction), and z-axis (supero-inferior direction) were respectively 0.56 mm (SD = 0.42), 0.77 mm (SD = 0.45) and 0.65 mm (SD = 0.61). ConclusionA high degree of accuracy between the virtual plan and the immediate postoperative result was observed. According to our results, PSI can be used safely with accuracy in MASO as an adjunct to other conventional orthognathic procedures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Stomatology, Oral and Maxillofacial Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.