Abstract

PurposeRespiratory-induced tumor motion of upper gastrointestinal (GI) tumors during radiation therapy is often assessed using a single 4-dimensional computed tomography (4D-CT) and presumed to be representative during fractionated treatment regimens. The purpose of this study was to examine the intra- and interfraction correlations of tumor motion between pretreatment 4D-CT and real-time fiducial-based motion tracking in patients treated with fractionated stereotactic body radiation therapy (SBRT) for upper GI malignancies. Methods and materialsFourteen patients with upper GI tumors underwent fractionated SBRT using the CyberKnife radiosurgical system with Synchrony respiratory motion management. Before treatment, each patient underwent a free-breathing 4D-CT scan and fiducial motion was tracked for each phase of the respiratory cycle. Real-time fiducial positions recorded during delivery of each SBRT fraction were extracted from the CyberKnife planning system. Displacements were compared between those predicted by 4D-CT and those recorded by Synchrony during treatment in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions. ResultsThe 4D-CT scans demonstrated little correlation with real-time mean fiducial displacement as determined by Pearson correlation with coefficients of 0.45, 0.52, and 0.63 in the SI, AP, and LR directions, respectively. Cohort-averaged maximum fiducial displacements based on 4D-CT and real-time tracking were measured to be 3.86 ± 1.40 mm versus 10.73 ± 7.03 mm, 2.29 ± 1.02 mm versus 4.44 ± 3.33 mm, and 1.45 ± 0.49 mm versus 2.67 ± 2.49 mm in the SI, AP, and LR directions, respectively. Mean fiducial displacements were greater than that predicted by the maximum displacements on the corresponding 4D-CT scan in 39%, 22%, and 25% of SBRT fractions in the SI, AP, and LR directions, respectively. ConclusionsComparison of 4D-CT with real-time fiducial tracking demonstrated significant inter- and intrafractional discrepancies, particularly in the SI direction, which could result in compromise of target coverage when planning with a single free-breathing 4D-CT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.