Abstract

Background Phase-contrast magnetic resonance imaging (PC-MRI) provides a powerful method for the quantification of blood velocity. Accuracy of flow measurement with PCMRI has been validated with several techniques such as Doppler ultrasound and electromagnetic flowmeters. However, these methods suffer from low accuracy, especially in pulsating flows where short response times are required. Methods Herein, a series of detailed experiments are reported for validation of MR measurements of steady and pulsatile flows with stereoscopic particle image velocimetry (SPIV) on three different stenotic models with 50%, 74%, and 87% area occlusions. Mean inlet Reynolds number was 190 for both steady and pulsatile cases, mimicking the flow of the human common iliac artery. Axial PC-MRI images were acquired at three sites: inlet (two diameters proximal to the stenosis), throat, and outlet (two diameters distal to the stenosis) using a 3T TX Achieva Philips MRI scanner with slice thickness = 4 mm, resolution = 1 × 1 mm, TE/TR = 3.0/4.0 ms, field of view =6 4 ×6 4 mm, and velocity encoding (Venc) = 30-200 cm/s depending on the imaging section. For SPIV purposes, a laser light sheet was passed perpendicular to the axis of the phantom to illuminate the flowing fluorescent particles (Fig 1). A set of image pairs were captured using two cameras looking at the phantom at different angles and the fluid velocity was extracted using a cross-correlation scheme, yielding a nominal spatial resolution of 0.2 mm for the velocity data. The temporal resolution of pulsatile flow measurements was 25 ms, corresponding to 40 measurements per second. Results Agreement between PC-MRI and SPIV was demonstrated for both steady and pulsatile flow measurements at the inlet by evaluating the linear regression between the two methods, which showed a correlation coefficient of >0.99 and >0.96 for steady and pulsatile flows, respectively. The difference between SPIV and PC-MRI measurements for steady and pulsatile mean flows was less than 5% for both inlet and throat and showed good agreement in all cases (Fig 2). The agreement, however, was weaker at the outlet especially for the 87% stenosis. The flow rate error distal to the stenosis was shown to be a function of narrowing severity. Conclusions Our experiments revealed that the most accurate measures of flow by PC-MRI are found at the throat of the stenosis. This study also illustrates that SPIV provides an excellent approach to in-vitro validation of new or existing PC-MRI flow measurement techniques. Funding

Highlights

  • Phase-contrast magnetic resonance imaging (PC-MRI) provides a powerful method for the quantification of blood velocity

  • Axial PC-MRI images were acquired at three sites: inlet, throat, and outlet using a 3T TX Achieva Philips MRI scanner with slice thickness = 4 mm, resolution = 1 × 1 mm, TE/TR = 3.0/4.0 ms, field of view = 64 × 64 mm, and velocity encoding (Venc) = 30-200 cm/s depending on the imaging section

  • The difference between stereoscopic particle image velocimetry (SPIV) and PC-MRI measurements for steady and pulsatile mean flows was less than 5% for both inlet and throat and showed good agreement in all cases (Fig 2)

Read more

Summary

Background

Phase-contrast magnetic resonance imaging (PC-MRI) provides a powerful method for the quantification of blood velocity. Accuracy of flow measurement with PCMRI has been validated with several techniques such as Doppler ultrasound and electromagnetic flowmeters. These methods suffer from low accuracy, especially in pulsating flows where short response times are required

Methods
Results
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call