Eastham and Rhodes published results of loss measurements on transposed superconducting NbTi cables and concluded basing on an extrapolation to very large numbers of wires that transposed superconductors could be used favourably in cables for power transmission. There are some reasons to question the correctness of their extrapolation. We calculated losses for transposed superconductors in self field and got results different from those of Eastham and Rhodes. Loss measurements were performed the results of which give evidence for the correctness of our calculations. Our results lead to the conclusion that the use of transposed cables of irreversible type 2 superconductors for power transmission is not advantageous.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.