Abstract
ABSTRACT This paper gives a study of line harmonics generated by three-phase half controlled bridge converters feeding separately excited D.C. motor. Analytical expressions for line current are given and dominant current and voltage harmonics have been computed for a typical system. The study shows that current has predominant low order harmonics, the second harmonic being significantly large as compared to other harmonics. The line voltage, however, has significant higher order harmonic components as well Line current harmonics are dependent on motor operating speed, whereas the voltage distortion factor is nearly independent of speed. On the other hand, percent current harmonics are nearly independent of torque, but the voltage harmonics and voltage distortion factor are dependent on load torque.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.