Abstract

Abstract Background The most common activating B-raf mutations (T1799A point mutation) lead to a substitution of valine (V) to glutamic acid (E) at the position 600 of the amino acid sequence. This oncogenic mutation in the B-raf gene constitutively activates the MAPK signaling pathway which results in increased proliferation and inhibition of apoptosis. B-raf V600E mutation was described in approximately 8% of all solid tumors (43% melanomas, 39-67% papillary thyroid carcinomas and 12% colorectal adenocarcinomas). Currently, the gold standard to identify B-raf mutations is sequencing of the tumor DNA. However this method is not practical for routine clinical detection due high risk of contamination and low sensitivity. Recent development of therapeutic intervention using B-raf inhibitors requires an accurate and rapid detection system for B-raf mutations. Methods Here we developed a new methodology for the rapid and reliable detection of B-raf (V600) mutations by combination of the modified real-time PCR primers, peptide nucleic acid (PNA) clamping and MGB probe, named of PM-PCR method. In this assay, the mutant gene is selectively amplified by the modified PCR primers and the amplicon extending signals are collected by the taqman-MGB probe in a real-time fashion, while the amplification of wild-type B-raf DNA is completely blocked by the specifically designed PNA with a higher annealing temperature. The assay procedure includes only one step of sample loading to avoid potential contamination. The PM-PCR method can detect 3-10 copies of the mutant gene stably in somatic cells with background of a total of 10ng wild-type genomic DNA. Tumor samples from 97 patients with malignant melanoma (N=20) and papillary thyroid carcinoma (N=78) were evaluated for the B-raf V600mutation. Genomic DNA was extracted from FFPE tissue sections and analyzed by PCR amplification followed by Sanger sequencing for comparison. Results Among the 97 tested samples, 74% (72/97) of them were positive for B-raf V600 mutation detected by our ARMS-PM assay, while 60.8% (59/97) were detected positive by Sanger sequencing. All the 25 negative cases detected by our assay were confirmed by Sanger sequencing with a concordance rate 100% (25/25). The overall concordance between our assay and Sanger sequencing was (87%) . Conclusion We have developed a new method for detection of B-raf V600 mutation by combination of the modified real-time PCR primers, PNA and MGB probes (PM-PCR method). The new assay demonstrates significantly improved sensitivity and feasibility for clinical application. <!–EndFragment–> Citation Format: Xiujuan Wang, Hui Lan, Qi-Lin Chen, Wei-Tao Duan, Shanshan Zhao, Dehua Yu. A highly sensitive, repaid and reliable assay for detection of human B-raf (V600) mutations. [abstract]. In: Proceedings of the 105th Annual Meeting of the American Association for Cancer Research; 2014 Apr 5-9; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2014;74(19 Suppl):Abstract nr 1511. doi:10.1158/1538-7445.AM2014-1511

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call