Abstract

In this research, the abnormal magnetic signals were detected in dynamic tension tests on the ferromagnetic material specimens, in order to study the characterization method of abnormal magnetic signals for the crack propagation life. It is indicated that fatigue crack length a is linear with the peak-peak value ΔHpa(y) of abnormal magnetic signals. The ΔHpa(y) of fatigue crack and the gradient of magnetic field intensity k increase with the increase of fatigue cycle number. Therefore, ΔHpa(y) and k are confirmed as the key parameters of characterizing crack propagation life. Then, a life prediction model of abnormal magnetic signals for the crack propagation life is founded based on the Paris equation. The maximum error between measured values and calculated values is less than 15%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.