Abstract

To report a case of late failure of a posterior segment placed Ahmed valve in a uveitic eye with a corneal graft and a minimally invasive, ab interno approach in restoring valve function, pressure control, and preservation of vision. Case report. A 25 gauge trans-conjunctival 3-port pars plana vitrectomy was performed to inspect and clean the ostium of the Ahmed valve of any vitreous debris. The Ahmed valve was not disturbed externally and conjunctival dissection was not performed. A 27-gauge blunt cannula was introduced through the vitrector site and used to cannulate the tube and flush it with balanced salt solution. A bleb was immediately re-established and all instruments were removed requiring no sutures. Intraocular pressure returned to target levels and a filtration bleb was re-established. Corneal graft clarity was restored with resolution of preoperative microcystic edema. Postoperative inflammation was minimal and vision was restored. A nonfunctioning tube shunt residing in the vitreous cavity may be revised ab interno without disturbing the shunt placement or the conjunctiva under which it resides to re-establish filtration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.