Abstract

The equations of state tables used in Inertial Confinement Fusion Capsule design tools are highly dependent on the cold curve in the multimegabar pressure range. Original ab initio molecular dynamic simulations were performed to get accurate cold curves of glow-discharge polymer (GDP) plastics. Furthermore the effect of oxygen absorption by GDP structure is studied on the cold curve, as well as its impact on the Hugoniot curves. Results are compared with the Hugoniot experimental data obtained in a recent experiment at the LULI2000 laser facility in France. This study leads to improve the equation of states knowledge of ablator materials, which is of primary importance for NIF and LMJ experiments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.