Abstract
Use of submarine outfall pipelines became more common since World Bank Group issued a new guideline for maximum emissions levels for thermal power plants in 1998 (van Dijk, 2005). The more restrictive levels for temperature increase at the receiving water, requires outfall systems to conduct the water down to greater depths to achieve the required dilution standard. However, air entrainment control into outfall pipes could be challenging, especially for discharges with high flowrates for which conventional deaeration chambers become too large. The problem could turn more difficult in coastal shelf areas at seismic zones, where the hydraulic height of the incoming flow must be effectively controlled and the design not only has to pursue hydraulic objectives but also stability requirements for these massive structures subjected to relevant seismic thrusts. A vortex drop structure was designed for the cooling water discharge system of a thermal power plant in Mejillones Bay, Chile. The structure addresses the elevation difference between the return flow pipe and the ocean outfall pipelines while adhering to the spatial restrictions at the project site. Energy dissipation as well as limitation of air entrainment into the outfall pipelines were critical design considerations. Tests where done on a 1:12.5 scale (Froude) physical model. Prototype structure is under construction. Operation is planned to start on mid-2018.
Highlights
Use of submarine outfall pipelines became more common since World Bank Group issued a new guideline for maximum emissions levels for thermal power plants in 1998
VORTEX DROP STRUCTURE A variable section vortex shaft and a tangential inlet ramp based on Brooks & Blackmer (1962) was considered and adapted to the project requirements following design recommendations by Hager (1990)
PHYSICAL MODEL AND FINDINGS A physical model study was conducted at Instituto Nacional de Hidraulica de Chile (INH) to validate the design of the discharge system
Summary
Use of submarine outfall pipelines became more common since World Bank Group issued a new guideline for maximum emissions levels for thermal power plants in 1998 (van Dijk, 2005). VORTEX DROP STRUCTURE A variable section vortex shaft and a tangential inlet ramp based on Brooks & Blackmer (1962) was considered and adapted to the project requirements following design recommendations by Hager (1990).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.