Abstract

For double-sided LCC compensation topology, it is not easy to maintain the output current and output voltage constant over the variation of coupling coefficient and load. Consequently, in this article, a unique design approach is presented. With the presented method, whether during a constant current output procedure or constant voltage output procedure, the resonant frequency maintains constant and cannot be affected by the coupling coefficient and load condition. In addition, the transmission gain is kept constant in different misalignment by the phase shift modulation. Zero voltage switching with the minimum reactive current can be implemented by the switch-controlled capacitor (SCC) regardless of the coupling coefficient and owing to the constant phasor of the current flowing the SCC, the control system of SCC is greatly simplified. Finally, a 60 W prototype is designed to verify the validity of the theoretical analysis. From the results of the experiment, when the coupling coefficient range is between 0.13 and 0.2, the fluctuation factors of output current and output voltage are only 0.5% and 1.0%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.