A tilted angle polarization type piezoelectric transducer (TAPP) is newly suggested to generate the Lamb waves in thin plate without wedge. The tilted angle between the TAPP and the aluminum plate is easily determined by Snell's law. Our new type TAPP with a tilted angle of 50° for S0 mode Lamb wave generation was specially manufactured. Preliminary experiments have been performed to examine the usefulness of our TAPP. As a result, efficient radiation of S0 mode Lamb wave from TAPP was confirmed and was clearly identified by the wavelet transform analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.