AbstractThe operation of a temperature/strain transducer, called “duplex gauge”, based on two electrical resistance strain gauges, that are temperature compensated for use on materials with different coefficients of linear expansion, was briefly recalled. Three steel specimens were equipped with “duplex gauges” and were subjected to temperature variations and no external loads were applied. The chosen experimental setup (i) to measure the outputs of the gauge temperature compensated for steel and titanium silicate and (ii) to impose known temperature, assured good accuracy and precision in evaluation of the temperature calibration curve. The obtained results showed that the strain differences could be considered, at least for the experimental arrangement examined, a linear function of temperature over the range of 20 to over 140°C. The prepared calibration chart, that allows the correction of temperature induced apparent strain, will be used in future research when generic temperature and strain fields are applied to specimens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.