Abstract

EUV mask absorber sidewall angle should be measured for mask Optical Proximity Correction and shadow effect estimation. Hence, verifying the three-dimensional profile of mask topography has become a challenge in EUV mask inspection. This paper evaluates EUV mask sidewall angle measurement by Field-Emission Critical Dimension (CD)-Scanning Electron Microscope (SEM) using JEOL JSM-7401F. SEM only produces two-dimensional gray images. Forming three-dimensional profiles from these images is a critical requirement for the sidewall angle measurement. To obtain three-dimensional information, absorber edge width has to be measured first to measure sidewall angle. We can calculate absorber sidewall angle with the exactly measured edge width and absorber height. Edge width narrows with steeper sidewall angle. We used the image processing function of Matlab to obtain absorber edge width accurately. In the end, every measured sidewall angle was compared to Transmission Electron Microscope (TEM) images to evaluate the validity of SEM results. Measured sidewall angles by SEM and TEM cross-section images have average tolerances of 0.62 degrees.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.