Abstract

This study aimed to create an animal model of type Ia endoleak that creates persistent problems after thoracic endovascular aortic repair. In six swine, thoracic aortic aneurysms were created using the harvested jugular vein. We created a type Ia endoleak using a composite stent-graft comprising the first stent-graft (reverse-tapered: thicker part, 16mm; thinner part, 10mm) and the second stent-graft (tapered: thicker part, 18-20mm; thinner part, 16mm). This double-component stent-graft was deployed in the abdominal aorta and then moved upward to the proximal entry site of the thoracic aneurysm using the inflated balloon for precise positioning. After the surgical procedure and on postoperative day 8, aortography was performed to detect residual endoleak, and then the swine were euthanized. A stable aneurysm (mean size of all aneurysms, 16.8 ± 1.72mm × 11.8 ± 2.32mm) and type Ia endoleak were successfully observed in all swine. A single stent-graft was sufficient in one of the six swine. A novel technique to create a type Ia endoleak model can be successfully developed in swine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.