Abstract

The basic synchronizing pulse in the P.P.A., tying the injection pulse and the R. F. to the magnetic field, is derived from the total current flowing through one of the Accelerator magnets. This pulse is generated in a biased toroidal coil wound on a supermalloy core, by the magnetic field H(t) created by the magnet current in a coaxial conductor. This method has provided us with a synchronization signal pulse with excellent long term stability and very little time-jitter. Part of the time-jitter may be attributed to the variations of dH/dt at the time of the reversal of the magnetization of the core due to variations of Imin in the magnets. A method has been developed to effectively cancel out the dH/dt effect in the supermalloy core.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.