Abstract

After the Fukushima accident, the importance of an emergency power supply for a nuclear power plant has been emphasized more. In order to maximize the performance of the existing emergency power source in operating nuclear power plants, adding a waste heat recovery system for the emergency power source is suggested for the first time in this study. In order to explore the possibility of the idea, a comparison of six supercritical carbon dioxide (S-CO2) power cycle layouts recovering waste heat from a 7.2 MW alternate alternating current diesel generator (AAC DG) is first presented. The diesel engine can supply two heat sources to the waste heat recovery system: one from exhaust gas and the other from scavenged air. Moreover, a sensitivity study of the cycles for different design parameters is performed, and the thermodynamic performances of the various cycles were evaluated. The main components, including turbomachinery and heat exchangers, are designed with in-house codes which have been validated with experiment data. Based on the designed cycle and components, the bottoming S-CO2 cycle performance under part load operating condition of AAC DG is analyzed by using a quasi-steady state cycle analysis method. It was found that a partial heating cycle has relatively higher net produced work while enjoying the benefit of a simple layout and smaller number of components. This study also revealed that further waste heat can be recovered by adjusting the flow split merging point of the partial heating cycle.

Highlights

  • The earthquake that occurred in Japan on 11 March 2011 induced a tsunami with several waves whose height reached more than ten meters

  • Another 800 kW diesel generator in the turbine building is installed for supplying power to non-Class 1E as well if the emergency diesel generators (EDG) system becomes unavailable, alternating current diesel generator (AAC DG) is electrically connected to operate safety systems instead of failed EDG

  • The S-CO2 cycle is recently considered as the potential power cycle of conventional and renewable energy systems such as fossil fuel power plants, concentrated solar power systems, geothermal power plants, fuel cells, generation nuclear power plants, and ship propulsion application

Read more

Summary

Introduction

The earthquake that occurred in Japan on 11 March 2011 induced a tsunami with several waves whose height reached more than ten meters. The target nuclear power plant to apply a waste heat recovery system is APR 1400 that is the abbreviation of “Advanced Power Reactor with an electrical power output of 1400 MW” It is a pressurized water-cooled reactor developed in Korea. Another 800 kW diesel generator in the turbine building is installed for supplying power to non-Class 1E as well if the EDG system becomes unavailable, AAC DG is electrically connected to operate safety systems instead of failed EDG.

Schematic
Cycle Layout and Analysis Method
Assumptions and Constraints
Sensitivity Analysis of S-CO2 Cycles
Simple Recuperation Cycle
Simple Recuperation Cycle with SA Heat
Modified Recompression Cycle with SA Heat
NetSA work dependence
4-8: Re-Compressor
Partial Heating Cycle
Partial Heating Cycle with SA Heat
15. Configuration
Modified Partial Heating Cycle with SA Heat
18. Configuration
Discussion and Summary
Turbomachinery Design
Heat Exchanger Design
Heat that
Design
Off-Design Analysis
Findings
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call