Abstract

A combined-sewer overflow (CSO) is a significant contributor of contamination to surface waters. During a rain event, the flow in a combined sewer system (CSS) may exceed the capacity of the intercepting sewer leading to a wastewater treatment plant, thus releasing a mixture of storm water and raw sanitary wastewater into the receiving water. As CSOs contain untreated domestic, commercial, and industrial wastes, as well as surface runoff, many different types of contaminants can be present. Because of these contaminants and the volume of the flows, CSOs can cause a variety of adverse impacts on the physical characteristics of surface water, impair the viability of aquatic habitats, and pose a potential threat to drinking water supplies. The resulting short-term problems are poor aesthetics (floatables, turbidity, oil and grease), and beach closure due to increased harmful bacteria levels. The long term impacts include reduced dissolved oxygen in receiving waters, eutrophication and sediment contamination. Since CSO is considered to be a major source of water quality impairment for the receiving waters, much attention has been directed to reducing the quantity and quality of CSO discharged to meet the Ministry of Environment guidelines. There are several approaches to control the quantity and quality of CSO. The selection of a particular treatment technology depends on various factors such as site conditions, CSO characteristics, receiving water requirements. One of the emerging options is the vortex separator technology for High Rate Treatment (HRT) facilities at overflow location. There are many devices for CSO control in different trade names where vortex separator technology has been used (e.g. EPA Swirl Concentration, FluidSep(TM), Storm King(TM), CDS®). This study articulates the different CSO control technologies with emphasized [sic] on vortex separator technology. The City of Niagara Falls HRT pilot project for CSO control to the Niagara River is presented as a case study in this report. The performance of two HRT devices - Storm King(TM) and CDS® are evaluated in the pilot project. Analytical Probabilistic Model has been used a a tool in this study to evaluate the potential pollution reduction at the Niagara Falls CSO system.

Highlights

  • Rummnan, Nawshin, "A study on vortex separator technology to control combined sewer overflow" (2005)

  • This Thesis Project is brought to you for free and open access by Digital Commons @ Ryerson. It has been accepted for inclusion in Theses and dissertations by an authorized administrator of Digital Commons @ Ryerson

Read more

Summary

Introduction

Nawshin, "A study on vortex separator technology to control combined sewer overflow" (2005).

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call