Abstract

The reaction mechanism between 0.1 MPa ClF3 gas and Ni was investigated in the temperature range of 473–873 K for 0–120 h. The kinetic corrosion behavior of Ni metal under 0.1 MPa ClF3 gas changed markedly at the point of 823 K. The reaction temperature is the most important factor in the corrosion behavior of metals with oxidative gas. As a result, the recommended maximum temperature to use Ni in 0.1 MPa ClF3 gas was estimated to be 748 K.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.