Abstract

The effect of high inlet solid loadings on cyclone pressure drop and separation efficiency was studied. The particles used were FCC catalyst. An extended range of concentrations, up to 20 kg of solids/kg of gas was used, well beyond the loading range reported before. The average entrance velocities were 7, 18 and 27 m/s. The experiments showed that, in the range of concentrations tested, the cyclone pressure drop for the solids laden air flow was about 47% of that for clean air. A trend of increasing separation efficiency with concentration was observed, up to 12 kg of solids/kg of gas, above which, the efficiency decreased. At test conditions, the collection efficiency was higher for the entrance velocity of 18 m/s than for 27 m/s.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.