Abstract

Experimental studies have been conducted on pressure drop and collection efficiency of a cyclone separator with different inlet vanes. The results indicated that all the inlet vanes reduce the cyclone pressure drop and also influence the collection efficiency in various degrees. Cyclone pressure drop decreases when dust concentration in the gas increases, and when an inlet vane is installed. 3#, 4# inlet vanes cause a higher pressure drop reduction, and a lower collection efficiency than without an inlet vane; Of all the inlet vanes, the effect of 2# on pressure drop reduction is in the second place and has no reduction in collection efficiency; 1# inlet vane has effect on pressure drop within a limited certain conditions but has the highest collection efficiency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.