Abstract

With the rapid development of microelectromechanical systems (MEMS) technology, materials such as silicon, metal, and polymers are widely used in the MEMS field. One of the reliability concerns related to Si MEMS is unwanted wear and adhesion. Therefore, SiC film is a possible choice for surfaces because of its favorable friction and wear properties such as used in cutting tool and transmission system of wind turbine. In this study, biocompatible SAM film (ODS) was used to decrease the adhesion force and the friction coefficient of SiC surface. Experimental results show that ODS can increase the contact angle and decrease the surface roughness value of SiC surfaces for the different roughness values and roughness directions. For Si, SiC film and SAMs film on surfaces, larger normal forces lead to smaller friction coefficients and cross roughness pattern have a smaller friction coefficient than that of straight roughness pattern. In addition, ODS film can decrease the friction coefficient on cross topography with relative small roughness value more effectively than can straight topography of SiC surfaces.