Abstract
Background: Laryngoscope is an instrument to facilitate placement of endotracheal tube which finds its use both in OTs and in crash carts for emergency resuscitation of patients. The blade of the instrument comes in contact with the mucosal surface during this procedure. Yet, there is an absence of clear cut guidelines for disinfection of different parts (blade and handle) of this instrument. Materials and methods: This observational prospective study was conducted over a period of 5 months on previously used and disinfected laryngoscopes placed in the crash carts of various areas (emergency, ICUs) of our hospital. Swabs were collected from three different parts of each laryngoscope: surface of the blade (A), front part of the handle top (B), and front part of the handle's knurled surface (C). Bacterial growth and identification were noted using standard microbiological techniques. Data were entered and analyzed using standard MS Excel sheet. Results: In the study, 213 samples (71 each from A, B, C sites) were obtained from laryngoscopes from various areas of the hospital of which 32.4% were contaminated. The highest percentage of contaminated laryngoscopes belonged to Emergency department, a known high throughput area. Swabs from blades were positive in 16.9% (12/71) cases, from light in 14.08% (10/71) cases and from handle in 18.3% (13/71) cases. Among the organisms isolated, Coagulase negative Staphylococcus was the commonest (37.1%) followed by MSSA (22.9%) and MRSA (20%) from various sites of the laryngoscopes. Conclusion: A sensitization towards proper cleaning of laryngoscopes from crash carts is a must. Centralized disinfection services of all the parts of this instrument are a must for ensuring proper sterility.
Highlights
Laryngoscope is an instrument containing a handle and blade with a light source useful to visualize the vocal cord to facilitate placement of endotracheal tube which finds its use in OTs during general anesthesia and in crash carts for emergency resuscitation of patients
This is an observational, prospective study conducted over a period of 5 months from January to May 2021, to find out the thoroughness of cleaning of the laryngoscope used in the crash carts of various areas
For catering to huge requirement of ICUs because of the heavy foot fall our hospital has many different ICUs designated as Burn ICU (BICU), Gastrosurgery ICU (GICU), Neurosurgical ICU(NSICU), Surgical ICU (SICU), Medicine ICU (MICU)
Summary
Received September 8, 2021; Revised November 24, 2021; Accepted December 13, 2021. Cite This Paper in the following Citation Styles (a): [1] Mausum Ranjan Behera, Tushar Bhutada, Kundan Kumar Sahu, Sarita Otta , "A Study of Bacterial Flora Present on Disinfected Crash Cart Laryngoscopes," Universal Journal of Public Health, Vol 9, No 6, pp. (b): Mausum Ranjan Behera, Tushar Bhutada, Kundan Kumar Sahu, Sarita Otta (2021). A Study of Bacterial Flora Present on Disinfected Crash Cart Laryngoscopes. Universal Journal of Public Health, 9(6), 431 - 435.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.