Abstract
Four ash samples which were deposited on four different locations in the atmospheric fluidized bed combustor, FBC, system at the TVA Shawnee Steam Plant near Paducah, KY, were employed in the present study. The SDT/MS and XRD techniques were applied to idenfity the sample composition and the mechanism that form the deposits. The major compound in the deposits from convection pass inlet, superheater and multiclone inlet was CaSO 4, and the predominant minor compound was CaO in the samples. Also, CaS was found in the deposits from superheater by XRD analysis. In the case of recycle feed pipes, Ca(OH) 2 and CaCO 3 were the major components, and CaSO 4 and CaO the predominant minor compound in the deposits. The combined SDT/MS with XRD results are useful techniques for identification of unknown ash samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.