Abstract
Objectives: To compare sliding friction of prototype 0.018-inch fiber-reinforced polymer composite (FRPC) archwire with 0.018-inch nickel titanium archwire using various bracket-arch wire combinations. Materials and Methods: Two wires were tested against four different brackets (3M Gemini Twin bracket; 3M Clarity metal-reinforced ceramic bracket; Ormco Inspire ICE ceramic bracket; and 3M SmartClip) using the Universal testing machine to study and compare frictional characteristics. Results: There was no significant difference noted for the frictional wear generated between the various archwire and bracket groups ( P = 0.542). No statistical significance was detected within individual archwire-bracket groups. A multiple comparison of groups showed significant difference in frictional wear. Least significance difference multiple comparison revealed statistical significance ( P Conclusion: FRPC and NiTi wire show comparable frictional wear when used with ICE, Gemini, Clarity, and SmartClip brackets.