Abstract

The deployment of low-carbon hydrogen in gas grids comes with strategic benefits in terms of energy system integration and decarbonization. However, hydrogen thermophysical properties substantially differ from natural gas and pose concerns of technical and regulatory nature. The present study investigates the blending of hydrogen into distribution gas networks, focusing on the steady-state fluid dynamic response of the grids and gas quality compliance issues at increasing hydrogen admixture levels. Two blending strategies are analyzed, the first of which involves the supply of NG–H2 blends at the city gate, while the latter addresses the injection of pure hydrogen in internal grid locations. In contrast with traditional case-specific analyses, results are derived from simulations executed over a large number (i.e., one thousand) of synthetic models of gas networks. The responses of the grids are therefore analyzed in a statistical fashion. The results highlight that lower probabilities of violating fluid dynamic and quality restrictions are obtained when hydrogen injection occurs close to or in correspondence with the system city gate. When pure hydrogen is injected in internal grid locations, even very low volumes (1% vol of the total) may determine gas quality violations, while fluid dynamic issues arise only in rare cases of significant hydrogen injection volumes (30% vol of the total).

Highlights

  • The proposed study has provided a statistical assessment of the effect of deploying The proposed study has provided a statistical assessment of the effect of deploying hydrogen in existing gas networks

  • The results are derived by steady-state fluid dynamic hydrogen in existing gas networks

  • Two main cases were vestigated, the first of which assumes that NG–H2 mixtures are supplied to the system investigated, of which assumes that NG–H

Read more

Summary

A Statistical Assessment of Blending

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations

Background
Literature Review
Motivation and Objectives
Methodology
Synthetic Models of Distribution Gas Grids
Topology of the Synthetic Networks
Network reinforcement
Example topology generation:
Technical Parameters of the Synthetic Networks
Effect of Blending Hydrogen in Distribution Gas Grids
Case A
Case B
Distribution
Physical propertiesofofthe the H2–NG
10. Consistently with the previously analyzed drogen are illustrated in Figures
Findings
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have