Abstract

A stability-indicating HPLC assay method has been developed and validated for medroxyprogesterone acetate (MPA) in bulk drug and injectable suspension. An isocratic RP-HPLC was achieved on a Hichrom C 18 column (150 mm × 4.6 mm i.d., 5 μm) utilizing a mobile phase of methanol 0.020 M acetate buffer pH 5 (65:35, v/v) and a photodiode array detector at 245 nm. The stress testing of MPA was carried out under acidic and alkaline hydrolysis, and oxidation conditions. MPA was well resolved from its degradation products, a main related substance (megestrol acetate) and two preservatives (methyl paraben and propyl paraben) with the resolution ≥2. The proposed method was validated for selectivity, linearity, accuracy, precision and solution stability. The method was found to be suitable for the quality control of MPA in bulk drug and injections as well as the stability-indicating studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.