Abstract

An experimental technique that modifies the conventional split Hopkinson pressure bar has been developed for measuring the compressive stress-strain responses of materials with low mechanical impedance and low compressive strengths such as elastomers at high strain rates. A high-strength aluminum alloy was used for the bar materials instead of steel, and the transmission bar was hollow. The lower Young's modulus of the aluminum alloy and the smaller cross-sectional area of the hollow bar increased the amplitude of the transmitted strain signal by an order of magnitude as compared to a conventional steel bar. In addition, a pulse shaper lengthened the rise time of the incident pulse to ensure stress equilibrium and homogeneous deformation in the low-impedance specimen. Experimental results show that the high strain rate, compressive stress-strain behavior of an elastomeric material can be determined accurately and reliably using this technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.