Abstract
A simplified high-pressure liquid chromatographic method for determination of furose-mide in plasma and urine has been developed using a fluorometric detector directly coupled to the column effluent. The method includes an ether extraction from acidified biologic samples. The mobile phase used for chromatography on a reversed-phase column (C 18 hydro-carbon permanently bonded to silica particles) is sufficiently acidic to induce fluorescence of furosemide. The methylester of furosemide is employed as an internal standard. The sensitivity is 0.1 and 0.25 μg per ml plasma and urine, respectively. The applicability to pharmacokinetic studies of furosemide is shown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.