Abstract
Aiming at the effective evaluation of the detectability of Eddy Current Testing(ECT) probes utilized in the nondestructive evaluation of Steam Generator(SG) tubing in Pressurized Water Reactor(PWR) type nuclear power plant, a new approach has been developed in this paper based on a simplified relation newly proposed for connecting induced eddy currents in SG tubing to the exciting magnetic field. To approximate the effect of the eddy current perturbation due to a small surface breaking crack, the ring current model has been improved to consider the crack opening through introducing a new set of ring currents. The proposed new model and simplified relation were validated by comparing eddy current distribution and the scattering magnetic field predicted by the present method and those calculated by an accurate numerical code. The applications to the S/N ratio analyses of several ECT probes and to the simulation of scan signals show this new method is feasible in the actual design and optimization of ECT probes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.