Abstract

On the Madison Symmetric Torus magnetic fusion plasma experiment, frozen pellet injection is an established method of depositing deuterium fuel into the core of the plasma. To freeze deuterium gas into pellets, the injector is cooled to 10 K with a cryogenic helium refrigerator. To exhaust residual frozen deuterium following injection of each pellet, the injector is warmed by resistive heating to >18.7 K, the triple point of deuterium. Motivated by the desire to inject carbon-containing pellets, the injector was modified to allow the freezing and injection of methane. The triple point of methane, 90.7 K, is well beyond the capability of the resistive heating hardware. To supplement the resistive heating, a small, steady flow of room-temperature helium was introduced as a heat source. The flow rate was optimized to provide minimum and maximum injector temperatures of 24 and 95 K, respectively, sufficient for methane pellet formation and exhaust. The flow rate can easily be optimized for other gases as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.