A simple, sensitive and specific reverse-phase high-performance liquid chromatography (HPLC) assay for the simultaneous quantitative determination of omeprazole and its three metabolites in human plasma was developed and validated. This method provides excellent chromatographic resolution and peak shape for the four components and the internal standard within a 17 min run time. The simple extraction method results in a clean base line and relatively high extraction efficiency. The method was validated over the range of 2–2000 ng/mL, with 2.0 ng/mL as the lower limit of quantification. Within- and between-day accuracies for five different concentrations ranged from 95 to 102%, and 95 to 114%, respectively. Within- and between-day precision ranged from 1.1 to 6.3% and 0.5 to 6.2%, respectively. Simplicity and high throughput make this method suitable for clinical pharmacokinetic studies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.