Abstract

The new luminosity monitor of the DELPHI detector, STIC (Small angle TIle Calorimeter), was built using a Shashlik technique. This technique does not provide longitudinal sampling of the showers, which limits the measurement of the direction of the incident particles and the e — π separation. For these reasons STIC was equipped with a Silicon Pad Shower Maximum Detector (SPSMD). In order to match the silicon detectors to the Shashlik read out by wavelength shifter (WLS) fibers, the silicon wafers had to be drilled with a precision better than 10 μ m without damaging the active area of the detectors. This paper describes the SPSMD with emphasis on the fabrication techniques and on the components used. Some preliminary results of the detector performance from data taken with a 45 GeV electron beam at CERN are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.