Abstract

Gas temperature and water concentration are measured by a tunable diode laser sensor using a single laser near 1.4 μm. Temperature is determined from the ratio of absorption of a H 2O line pair near 7079.176 and 7079.855 cm −1, which are chosen using some selected criteria. The second harmonic detection of wavelength modulation spectroscopy (WMS-2 f) is employed to improve the sensor sensitivity and accuracy. Normalization of the 2 f signal with the 1 f signal magnitude is used to remove the need for calibration and correct for transmission variation due to beam steering, mechanical misalignments, soot, and windows fouling. An optimum laser modulation depth is selected to make the WMS-2 f signals of both lines as big as possible for the target test conditions. The influence of total pressure and water mole fraction is evaluated through theoretical simulations. The validation of the sensor is conducted in a controlled static cell, yielding an accuracy of 1.06% temperature and 1.9% for H 2O concentration. Burner experiments demonstrate the accuracy (1.2% for temperature and 3.2% for H 2O concentration) and potential utility of the system for combustion diagnosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.