Abstract
A self-aligned vertical Kelvin test resistor structure, which not only eliminates the horizontal current crowding but also avoids the misalignment error, is proposed and used to measure p/sub c/ of Al and Ti on Si. For the Al(1%Si)/n/sup +/-Si contact system, a specific contact resistivity of 1*10/sup -7/ Omega -cm/sup 2/ has been measured. For the TiSi/sub 2/ contacts, the TiSi/sub 2/(direct-reaction)/n/sup +/-Si contact offers a lower p/sub c/ than that of the coevaporated TiSi/sub 2//n/sup +/-Si contact, and p/sub c/ does not change even after the contacts are annealed to 900 degrees C. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.