Abstract
A vertical Kelvin test structure, which can be used to measure the true specific contact resistivity of a metallization system, is proposed and studied. For this test structure, the driving current flows "vertically," thus the sheet resistance and current crowding effects are eliminated and measurement on the true specific contact resistivity becomes possible. Experimental works show that this test structure gives a more linear relation between resistance and contact area than the conventional six-terminal test structure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.