Abstract
The goal of our study was to determine the frequency and type of transfusion reactions (TRs) as well as other hemovigilance activities reported at a tertiary care hospital in Turkey over a period of 3 years. In this retrospective study, the notification sheets of TRs reported to the institution's local hemovigilance system between December 2017 and December 2020 were analyzed. A total of 89,187 units of blood components were administered to patients during this period. A total of 197 TRs were reported to the hemovigilance system. The overall frequency of TRs was 0.22%. The most common TRs were allergic reactions (49.2%) and febrile nonhemolytic transfusion reactions (37.6%), respectively. Most of the adverse events were reported by clinical nurses. Our study showed that the frequency of TRs was low, and most were manageable reactions. We found that reporting of all TRs and continuous nursing education can help to strengthen the hemovigilance system. [J Contin Educ Nurs. 2021;52(12):581-588.].
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.