Abstract

The characterization and identification of compounds in complex real-world samples is quite difficult and new concepts and workflows are highly desirable. Retention indices (RIs) are widely used in gas chromatography (GC) to support the identification of unknown compounds. Several attempts have been made to introduce a similar concept for the second dimension in comprehensive two-dimensional (2D) GC (GC × GC) but, an easily applicable and robust system remains elusive.In the present study, a new RI system for GC × GC was developed. Polyethylene glycols (PEGs) were used in combination with a simple linear regression, with n-alkanes as reference points for virtually unretained compounds and PEG homologs as reference compounds for second-dimension RIs (PEG-2I). The n-alkanes were assigned a PEG-2I of zero and the distance between consecutive PEG homologs from PEG-2 (diethylene glycol) and higher were assigned a PEG-2I value of 10. We used ethylene glycol and PEG-2 through PEG-10 as reference compounds, thereby covering a PEG-2I range from 20.0 for ethylene glycol, over 50.0 for diethylene glycol (PEG-2) to 130.0 for decaethylene glycol (PEG-10); additional PEGs can be added to cover a wider polarity range. The PEG-2I system was initially evaluated using a 30 m × 0.25 mm non-polar (5% phenyl, 0.25 μm film thickness) first-dimension column and a 1.6 m × 0.18 mm polar (50% phenyl, 0.18 μm film thickness) second-dimension column. This system was validated for use with non-polar first-dimension columns and a semi-polar (50% phenyl) second-dimension column, and exhibited robustness to changes in the carrier gas flow velocity, oven temperature ramping rate, and secondary oven temperature offset. An average relative standard deviation of 2.7%, equal to a 95% confidence interval of 1.27 PEG-2I units, was obtained for the PEG-2I values of 72 environmental pollutants. Additionally, the system was found to be applicable over a wide range of boiling points (in the current case, from n-heptane to n-dotriacontane (C7–C32)) and can be used with various column dimensions. Changing the second-dimension column to either a narrower 0.1 mm column or a wider 0.25 mm column, yielded similar 95%-percentiles to that of the 0.18 mm column, differing by only 3.20 and 2.80 PEG-2I units, respectively. Moreover, methods for improving the system were suggested.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call