Abstract

A prototype system for the remote, in situ analysis of tritium in surface and ground waters has been developed at the Savannah River Site through the combined efforts of university, private industry, and government laboratory personnel under a project funded by the DOE/OTD. Using automated liquid scintillation counting techniques, the Field Deployable Tritium Analysis System (FDTAS) has been shown in laboratory and limited field tests to have sufficient sensitivity to measure tritium in water samples at environmental levels (10 Bq/L [{approximately}300 pCi/L] for a 100-minute count) on a near-real time basis. These limits are well below the EPA drinking water standard for tritium at 740 Bq/L (1) and lower than the normal upstream Savannah River tritium concentration of {approximately}40 Bq/L (2). The FDTAS consists of a fixed volume sampler (50 mL), an on-line water purification system, and a stop-flow liquid scintillation counter for detecting tritium in the purified sample. All operations are controlled and monitored by a remote computer using standard telephone line modem communications. The FDTAS offers a cost-effective alternative to the expensive and time-consuming methods of field sample collection and laboratory analyses for tritium in contaminated groundwater.