Abstract

We describe a reference device that provides accurate correlation between anatomic and functional brain images. The reference device, which generates fiduciary reference points on sequential scan planes, is positioned adjacent to the canthomeatal line of the subject and held in place by a glasses-like framework anchored to the external auditory meatus. The reference system was tested on 17 subjects undergoing 99mTc hexamethylpropylene amine oxime ([99mTc]HMPAO) brain single-photon emission computed tomography (SPECT) and cranial computed tomography (CT) scans. The centers of the caudate nuclei, thalami, brain stem, and cerebellar vermis were identified independently on CT and SPECT. The average difference +/- 1 SD between structure locations (x, y, and z) on SPECT and CT were calculated as 1.86 +/- 1.5, 2.16 +/- 1.4, and 1.83 +/- 1.9 mm, respectively. The clinical application of the method is showed by coregistration of images from SPECT to MRI. An example of sequential [99mTc]HMPAO brain SPECT scan sections precisely coregistered with MRI scan sections oriented parallel to and sequentially above the canthomeatal line illustrates the correlation between regional cerebral blood flow (rCBF) tracer activity on SPECT and normal anatomic structures. Test-retest activation paradigms in brain SPECT requires precise SPECT-to-SPECT image coregistration to evaluate changes in rCBF during activation. Precisely coregistered rest, 48-hour repeat rest [99mTc]HMPAO SPECT studies are shown to illustrate the normal intrasubject variability of tracer uptake. An example of the usefulness of image coregistration for evaluation of viable residual brain tumor and its application to tumor biopsy is presented. An example of developmental abnormalities identified by [99mTc]HMPAO brain SPECT is illustrated by a case of autistic disorder. An example of image coregistration in stroke and evaluation of cerebrovascular disease with Diamox (Lederle Laboratory Division, Pearl River, NY) cerebrovasculature stress testing is presented. The usefulness in epilepsy using a protocol whereby the tracer is injected during the ictal phase of seizure is presented. We conclude that the reference system provides an accurate, rapid, and noninvasive patient-specific method for correlating brain structure with brain function.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.