Abstract
The non-implantation bi-directional brain-computer interface (BCI) is a neural interface technology that enables direct two-way communication between the brain and the external world by both "reading" neural signals and "writing" stimulation patterns to the brain. This technology has vast potential applications, such as improving the quality of life for individuals with neurological and mental illnesses and even expanding the boundaries of human capabilities. Nonetheless, non-implantation bi-directional BCIs face challenges in generating real-time feedback and achieving compatibility between stimulation and recording. These issues arise due to the considerable overlap between electrical stimulation frequencies and electrophysiological recording frequencies, as well as the impediment caused by the skull to the interaction of external and internal currents. To address those challenges, this work proposes a novel solution that combines the temporal interference stimulation paradigm and minimally invasive skull modification. A longitudinal animal experiment has preliminarily validated the feasibility of the proposed method. In signal recording experiments, the average impedance of our scheme decreased by 4.59 kΩ, about 67%, compared to the conventional technique at 18 points. The peak-to-peak value of the Somatosensory Evoked Potential increased by 8%. Meanwhile, the signal-to-noise ratio of Steady-State Visual Evoked Potential increased by 5.13 dB, and its classification accuracy increased by 44%. The maximum bandwidth of the resting state rose by 63%. In electrical stimulation experiments, the signal-to-noise ratio of the low-frequency response evoked by our scheme rose by 8.04 dB, and no stimulation artifacts were generated. The experimental results show that signal quality in acquisition has significantly improved, and frequency-band isolation eliminates stimulation artifacts at the source. The acquisition and stimulation pathways are real-time compatible in this non-implantation bi-directional BCI solution, which can provide technical support and theoretical guidance for creating closed-loop adaptive systems coupled with particular application scenarios in the future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Neural Systems and Rehabilitation Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.