Abstract
Vertical displacement event (VDE) is one of the most important events related to disruptions. A real-time disruption prediction tool for VDE is presented in this article. Vertical growth rate is an essential parameter to describe vertical instability, which can be obtained based on the rigid plasma response model. A real-time vertical growth rate calculation system is built, which utilizes graphics process unit (GPU) parallel computation and reflective memory (RFM) boards communication with plasma control system (PCS). Based on real-time vertical growth rate calculation system, an alarm algorithm for detecting vertical instability is integrated into experimental advanced superconducting tokamak (EAST) PCS. It is designed to provide the capabilities of a switching control method and to trigger a warning signal in PCS when uncontrollable vertical instability is detected. Such a disruption prediction tool has been preliminarily applied in the 2019 EAST spring experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.