Abstract

Purpose: This study was undertaken to determine the appropriate timing and frequency of duplex ultrasound scanning after carotid endarterectomy (CEA) for the detection of high-grade stenosis caused by recurrent carotid stenosis or contralateral atherosclerotic disease progression. Methods: In 221 patients who underwent 242 CEAs, duplex scanning was performed before, during, and after operation (in 3-month to 6-month intervals). High-grade internal carotid artery (ICA) stenosis (peak systolic velocity, >300 cm/s; diastolic velocity, >125 cm/s; ICA/common carotid artery ratio, >4) prompted the recommendation for repair. An average of four postoperative scanning procedures was performed during a mean follow-up period of 27.4 months. Results: Intraoperative duplex scan results prompted the immediate revision of 12 repairs (4.9%), and one perioperative stroke (<1%) occurred. Six CEAs (2.7%) had asymptomatic recurrent stenosis (>50% diameter-reduction [DR]; systolic velocity, >125 cm/s) develop. Only one of six patients had >75% DR stenosis develop and underwent reoperation (<1% yield for CEA surveillance). The yield of surveillance of the unoperated ICA was higher ( P = .003), and 12% of unoperated sides had progressive stenosis (n = 21) or occlusion (n = 3) develop, which led to seven CEAs for high-grade stenosis. Disease progression to >75% DR stenosis was five times as frequent ( P =.002) in patients with >50% DR stenosis initially. All patients but one who required contralateral endarterectomy for disease progression had >50% ICA stenosis when first seen. During the follow-up period, no disabling strokes ipsilateral to an operated carotid artery occurred, but three strokes occurred in the hemisphere of the contralateral unoperated ICA. Conclusion: The yield of duplex scan surveillance after CEA was low. Only 13 patients (5.9%) had severe disease develop to warrant additional intervention. Progression of contralateral disease rather than restenosis was the most common abnormality that was identified. Duplex scanning at 1-year to 2-year intervals after CEA is adequate when a technically precise repair is achieved and minimal contralateral disease (<50% DR) is present. A policy of duplex scan surveillance and reoperation for high-grade stenosis was associated with a 1.6% incidence rate of disabling stroke during the follow-up period. (J Vasc Surg 1999;30:453-60.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.