Abstract

A 54-year-old man underwent aortic repair for the infected thoracoabdominal aneurysm with a woven Dacron graft (Vascutek, Renfrewshire, Scotland) treated with gentian violet. Four months later, he complained of sudden back pain, resulting in preshock status. Computed tomographic scans showed massive hematoma around the Dacron graft, suggesting graft rupture. Initially, emergency thoracic endovascular aortic repair was performed, which was subsequently followed by open repair. The Dacron graft had a small hole, which was completely compatible with the site contacting with the rib. The graft rupture was considered due to its friction against the rib. We report on a rare event of mechanical Dacron graft rupture after the thoracoabdominal aortic replacement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.