Abstract

ObjectiveIt is unclear whether supplemental oxygen and noninvasive ventilation respiratory support devices increase the dispersion of potentially infectious bioaerosols in a pressurized air medical cabin. This study quantitatively compared particle dispersion from respiratory support modalities in an air medical cabin during flight. MethodsDispersion was measured in a fixed wing air ambulance during flight with a breathing medical mannequin simulator exhaling nebulized saline from the lower respiratory tract with the following respiratory support modalities: a nasal cannula with a surgical mask, high-flow nasal oxygen (HFNO) with a surgical mask, and noninvasive bilevel positive airway pressure (BiPAP) ventilation. ResultsNasal cannula oxygen with a surgical mask was associated with the highest particle concentrations. In the absence of mask seal leaks, BiPAP was associated with 1 order of magnitude lower particle concentration compared with a nasal cannula with a surgical mask. Particle concentrations associated with HFNO with a surgical mask were lower than a nasal cannula with a surgical mask but higher than BiPAP. ConclusionsParticle dispersion associated with the use of BiPAP and HFNO with a surgical mask is lower than nasal cannula oxygen with a surgical mask. These findings may assist air medical organizations with operational decisions where little data exist about respiratory particle dispersion.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call