Abstract

Objectives: To compare the performance of a new coaxial catheter system with an echo-dense tip (Cook Echo-Tip® catheter) with a Wallace catheter during ultrasound-guided ET. Design: Prospective, randomized study Setting: Private academically affiliated infertility center. Patient(s): Two hundred fifty-one patients undergoing IVF-ET. Intervention(s): The patients underwent ultrasound-guided ET by a single physician with a standardized technique alternately using one of the two catheters. Main Outcome Measure(s): Implantation rates, pregnancy rates, ease of transfer, visualization, and status of catheter tip. Result(s): The echo-dense tip of the Cook Echo-Tip® catheter was consistently seen with ultrasound guidance, minimizing the need for catheter movement to identify the tip. Implantation rate (30% vs. 35%), clinical pregnancy rate (57% vs. 55%), and ongoing pregnancy rate (49% vs. 47%) were similar in both groups. Conclusion(s): The Cook Echo-Tip® catheter with its echogenic tip simplifies ultrasound-guided ET, but pregnancy success rates are similar to those obtained when a Wallace catheter is used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.