Abstract

A pulser has been designed to produce a 14 Hz sinusoid current pulse at a 2 s rate with peak amplitudes from 400 amps to 3750 amps, and a long term stability of ±400 mA. Short term stability is achieved by the use of a precision voltage regulator for the capacitor bank. This voltage regulator uses gate turnoff thyristors to control the charging current to the 13 mF capacitor bank. Load current is monitored with a precision dc current transductor. The peak value is read into a single chip microcomputer programmed to act as a digital regulator. The microcomputer calculates reference values for the capacitor bank charging supply and the capacitor bank voltage regulator.