Abstract

Serology to monitor Trichinella spp. infection in pigs reared in controlled system has been claimed as a possible diagnostic tool. However, no international biological standards or reference materials exist to validate in house tests or commercial kits, and to improve the inter-laboratory comparability for the serological detection of anti-Trichinella IgG in pigs. In this work, potential reference sera have been prepared from four experimentally infected pigs. Sera were tested, aliquot, lyophilized, and maintained at +4°C. Since one of the prerequisites for the development of any reference material is to plan and execute stability studies, isochronous studies for short and long term stability testing were carried out to evaluate the possible degradation effects of transportation and storage. The stability of the lyophilized serum samples at +4°C, was arbitrarily assumed. For the short term stability study, two units were stored at −20°C, +4°C, +20°C, and +50°C for 0, 1, 2, and 4 weeks, and then tested in duplicate. For the long term stability study, the same number of units and replicates per unit were stored at −80°C, −20°C, and +4°C for 0, 6, 12, 18 and 24 months. In both studies, unit samples were selected randomly and tested on the same day under repeatability conditions. The linear regression versus time for each serum at each studied temperature was analyzed and then slopes were tested for significance. Further, uncertainty of the short and long term stability was calculated for a shelf life period of one week and three years, respectively. For all sera but one, and for all the studied temperatures but +50°C, the data from the short term stability study indicate the absence of a significant trend that would hint at degradation. The slopes of the regression lines did not significantly vary from zero. Even if the uncertainty of the short term stability was variable among serum samples, the rate of degradation was considered acceptable. For the long term stability, slopes of the regression lines of two serum samples significantly varied from zero, indicating a trend of possible degradation during storage. The percentage of degradation deducted from the uncertainty of the long term study varied; however, two serum samples showed the lower rate of degradation at all the assayed temperatures. The most suitable temperatures for dispatching serum samples are −20°C, +4°C and +20°C; whereas, −20°C and −80°C are suitable temperatures for serum storage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.