Abstract
As the temperature span(△T) of a refrigerator with an active magnetic regenerator(AMR) of single magneto-caloric material is limited, in the current investigation, the multi-layer AMR consisting of Gd and Gd0.73Tb0.27 is studied to improve the refrigeration performance at a larger △T with the numerical method, where the experimental magneto-caloric properties are adopted for a better precision. Effects of Gd0.73Tb0.27 content (φ) and fluid flowrate (qV) on refrigeration capacity (qref,V) and coefficient of performance (COP), together with those of hot and cold reservoir temperatures (Tc and Th), are investigated. Besides, temperature contours of fluid and solid matrix are presented for discussions. The present study demonstrates that compared with AMR of pure Gd, the multi-layer AMR improves the qref,V and COP by ~167% and 57% at △T = 28K, respectively. Moreover, it is observed that qref,V of multi-layer AMR has a convex variation tendency with φ, and the maximum at Tc of 268K equals 874.7 kW/m3. As a contrast, COP has two peaks, and the optimal φ is almost independent of Tc, while it decreases with a rising Th. In addition, current investigation indicates that qref,V takes a lager value at a larger qV, while a smaller qV facilitates a good COP.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.