Abstract

A new style high voltage resistor divider made of saline solution has been constructed and tested. A coaxial construction is used on the low-voltage arm, as the signal extraction electrode, which can increase the attenuation ratio of the divider. The time response of divider limited by the stray parameter also can be improved. Comparing the results of calibrated experiment with the commonly used equal size copper sulfate dividers, the new probe has nearly five times increase in the attenuation ratio. The time response of the new style divider in the dimension of 30 mm in diameter and 400 mm in length can reach to 1 ns.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.